A multi-storey car park (also called a parkade, parking garage, parking structure, parking ramp, parking building, parking deck or indoor parking) is a building designed for car parking and where there are a number of floors or levels on which parking takes place. It is essentially an indoor, stacked parking lot. Parking structures may be heated if they are enclosed.
Design of parking structures can add considerable cost for planning new developments, and can be mandated by cities or states in new building parking requirements. Some cities such as London have abolished previously enacted minimum parking requirements.
Video Multi-storey car park
History
The earliest known multi-storey car park was opened in May 1901 by City & Suburban Electric Carriage Company at 6 Denman Street, central London. The location had space for 100 vehicles over seven floors, totaling 19,000 square feet. The same company opened a second location in 1902 for 230 vehicles. The company specialized in the sale, storage, valeting and on-demand delivery of electric vehicles that could travel about 40 miles and had a top speed of 20 miles per hour.
The earliest known multi-storey car park in the United States was built in 1918 for the Hotel La Salle at 215 West Washington Street in the West Loop area of downtown Chicago, Illinois. It was designed by Holabird and Roche. The Hotel La Salle was demolished in 1976, but the parking structure remained because it had been designated as preliminary landmark status and the structure was several blocks from the hotel. It was demolished in 2005 after failing to receive landmark status from the city of Chicago. A 49-storey apartment tower, 215 West, has taken its place, also featuring a multi-tiered parking garage.
Maps Multi-storey car park
Design
The movement of vehicles between floors can be affected by:
- interior ramps - the most common type
- exterior ramps - which may take the form of a circular ramp (colloquially known as a 'whirley-gig' in America)
- vehicle lifts - the least common
- automated robot systems - combination of ramp and elevator
Where the car park is built on sloping land, it may be split-level or have sloped parking.
Many car parks are independent buildings dedicated exclusively to that use. The design loads for car parks are often less than the office building they serve (50 psf versus 80 psf), leading to long floor spans of 55-60 feet that permit cars to park in rows without supporting columns in between. The most common structural systems in the United States for these structures are either prestressed concrete double-tee floor systems or post-tensioned cast-in-place concrete floor systems.
In recent times, car parks built to serve residential and some business properties have been built as part of a larger building, often underground as part of the basement, such as at the Atlantic Station redevelopment in Atlanta. This saves land for other uses (as opposed to a parking lot), is cheaper and more practical in most cases than a separate structure, and is hidden from view. It protects customers and their cars from weather such as rain, snow, or hot summer sunshine that raises a vehicle's interior temperature to extremely high levels. Underground parking of only two levels was considered an innovative concept in 1964, when developer Louis Lesser developed a two-level underground parking structure under six 10-storey high-rise residential halls at California State University, Los Angeles, which lacked space for horizontal expansion in the 176-acre (0.71 km2) university. The simple two-level parking structure was considered unusual enough in 1964 that a separate newspaper section entitled "Parking Underground" described the garage as an innovative "concept" and as "subterranean spaces". In Toronto, a 2,400 space parking lot below Nathan Phillips Square is one of the world's largest.
Car parks which serve shopping centres can be built adjacent to the centre for easier access at each floor between shops and parking. One example is Mall of America in Bloomington, Minnesota, USA, which has two large car parks attached to the building, at the eastern and western ends. A common position for car parks within shopping centres in the UK is on the roof, around the various utility systems, enabling customers to take lifts straight down into the centre. Examples of such are The Oracle in Reading and Festival Place in Basingstoke.
These garages often have low ceiling clearances, which restrict access by full-size vans and other large vehicles. On 15 December 2013, a man was killed during a robbery in the garage at The Mall at Short Hills in Millburn, New Jersey. The ambulance responding to the shooting was delayed because it was too large to enter the garage.
In the United States, costs for multi-storey parking structures are estimated to cost between $25,000 per space, with underground parking costing around $35,000 per space.
Structural integrity
Parking structures are subjected to the heavy and shifting loads of moving vehicles, and must bear the associated physical stresses. Expansion joints are used between sections not only for thermal expansion but to accommodate the flexing of the structure's sections due to vehicle traffic. Seismic retrofits can be applied where earthquakes are an issue.
Some parking structures have partly collapsed, either during construction or years later. In July 2009 a fourth-floor section failed at the Centergy building in midtown Atlanta, pancaking down and destroying more than 30 vehicles but injuring no-one. In December 2007, a car crashed into the wall of the deck at the SouthPark Mall in Charlotte, North Carolina, weakening it and causing a small collapse which destroyed two cars below. On the same day, one under construction in Jacksonville, Florida collapsed as concrete was being poured on the sixth floor. In November 2008, the sudden collapse of the middle level of a deck in Montreal was preceded by warning signs some weeks before, including cracks and water leaks. Parking structures are generally not subject to building inspections after being checked for their initial occupancy permit.
In October 2012 four people were killed and nine more injured when a parking structure under construction at a campus of Miami-Dade College in Florida collapsed, purportedly due to an unfinished column.
Precast parking structures
With the growth of multi-storey car parks since the middle of the twentieth century, many constructions of such structures have been using precast concrete to reduce the construction time. The design involves putting parking structure parts together. The parts of precast concrete include multi-storey structural wall panels, interior and exterior columns, structural floors, girders, wall panels, stairs and slabs. The precast concrete parts are transported using flatbed semi-trailers to the sites. The structural floor modules may need to be laid tilted during the transportation in order to cover as large floor area as possible while they can be easily transported on the roadways. The modules are lifted using precast concrete lifting anchor systems at the sites for assembly. Decorations may include using of covers to close the holes in the precast concrete that contains the lifting anchors, and installing facades to the exterior of the structures.
In modern construction of the precast modules, there are other features to improve the strength of the structure. An example is to use prestressed strands on post-tensioned concrete for the construction of the shear walls. Another example is the use of carbon-fiber-reinforced polymer to replace steel wire mesh to lighten the load and yield more corrosion resistant especially for the cold-climate areas which use salt for melting snow.
Architectural value
These structures are not usually known for their architectural value. As Architectural Record has noted, "In the Pantheon of Building Types, the parking garage lurks somewhere in the vicinity of prisons and toll plazas." The New York Times has labeled parking structures as "the grim afterthought of American design".
A handful of parking garages have received considerable praise for their design, including
- 1111 Lincoln Road, in the South Beach section of Miami Beach, Florida and designed by the internationally known Swiss architectural firm of Herzog & de Meuron.
- The Brutalist Preston bus station in the United Kingdom, which incorporates a multi-storey car park
Nomenclature
The term multistorey car park is used in the United Kingdom, Hong Kong, and many Commonwealth of Nations countries and commonly spelled with a hyphen. In the western United States, the term parking structure is used, especially when it is necessary to distinguish such a structure from the "garage" in a house. In some places in North America, "parking garage" refers only to an indoor, often underground, structure. Outdoor, multi-level parking facilities are referred to by a number of regional terms:
- Parking garage is used, to varying degrees, throughout the U.S.; and rarely, in Canada as well often referring to underground parking, and professionally by civil engineers;
- Parking deck is used mostly in the Southern United States.
- Parking ramp is used in the upper Midwest, especially Minnesota and Wisconsin, and has been observed as far east as Buffalo, New York.
- Parkade is widely used in Canada and South Africa
- Parking building is used in New Zealand.
Architects and civil engineers in the USA are likely to call it a parking structure, since their work is all about structures, and that term is the vernacular in some of the western United States. When attached to a high-rise of another use, it is sometimes called a parking podium. United States building codes use the term open parking garage to refer to a structure designed for car storage that has openings along at least 40% of the perimeter, as opposed to an enclosed parking garage that requires mechanical ventilation. Natural or mechanical ventilation provides fresh air flow to disperse car exhaust in normal conditions, or hot gas and smoke in case of fire.
Typically car park experts describe the number of car park floors in terms of "G+x". G stands for ground and x for the number of floors above ground. For example, G+5 is a multi-story car park structure with a ground floor and 5 floors above that, ie. a total of 6 floors.
Car Park Construction Types
- Concrete
- Steel Structure
- Automated (Mechanical)
Steel Structure Car Park
Structure car parks are car parks made of structural steel components connected to each other to carry the loads and provide full structural rigidity.
Steel is a high strength material requiring less material than other types of structures like concrete and timber. Steel construction features:
- Cost Savings: inexpensive to manufacture and erect, and requires less maintenance than traditional building methods.
- Speed: Allows construction/prefabrication off-site with rapid installation on-site. Some suppliers claim construction in days.
- Durability: Suppliers claim 50+ years lifespan.
- Removability: Steel car park structure could be designed to be removed at a later date.
- Expandability: Steel car park structures can be expanded easily at a later date.
- Creativity: Steel allows for long column-free spans
The ceiling slab of the steel structure car park is typically made of composite material such as corrugated steel sheets and concrete. The surface of the first-floor parking can be left bare or covered with epoxy or tarmac.
Foundationless/Modular Car Park Sytem
Demand, steel features, and innovation have led to the development of a foundationless, modular, removable steel car park structure.
Parking demand often grows quickly, significantly and sometimes unexpectedly. Modular steel car parks could be the proper solution if the surface area available is not sufficient and can be expanded upwards, or whenever it is not feasible to build up a multi-story parking. The development of the building concept of modular car parks came about by using the modular assembling method of vertical and horizontal elements (such as columns and beams) Modular car park structures are versatile and can be built in phases or in different sizes and shape. The solution makes it possible to develop a parking structure even in case of particular conditions or constraints, such as archaeological sites or city centres, because it allows:
- To virtually double the parking surface without leaving any footprint on the ground, as no settlement for excavations or traditional foundations is needed;
- To double the parking surface by means of a light steel single-deck car park system.
- Prefab modular components of the system make each project versatile and suitable for both large and small sized areas.
These parking structures are generally demountable and can be relocated to avoid making the choice of converting a surface to parking area irrevocably. They could be used as permanent structures or are conceived as temporary parking facilities for temporary parking demand needs. A number of parking decks have been demounted after a few years - to make room for the development of a permanent structure - and relocated to respond to local parking demand.
Automated parking
The earliest use of an automated parking system (APS) was in Paris in 1905 at the Garage Rue de Ponthieu. The APS consisted of a groundbreaking multi-story concrete structure with an internal elevator to transport cars to upper levels where attendants parked the cars. A 1931 Popular Mechanics article speculated an underground garage where the car was taken to a parking area by a conveyor then an elevator to shuttles mounted on rails.
The total cost of ownership of automated car parks needs to be carefully considered.
The actual cost of construction of automated car parks is typically higher than conventional car park structures, however, this can be offset by the higher space efficiency of automated car parks. The cost of the mechanical equipment needed to transport the cars needs to be added to the building cost. In addition, operation and maintenance costs of the mechanical equipment need to be added in order to determine the total cost of ownership. Other costs could be saved, for example, there is no need for an energy-intensive ventilating system, since cars are not driven inside and human cashiers or security personnel may not be needed. For naturally ventilated car parks structures, the ventilation equipment is not needed.
Automated car parks rely on similar technology to that used for mechanical handling and document retrieval. The driver leaves the car in an entrance module, and it is then transported to a parking slot by a robotic trolley. For the driver, the process of parking is reduced to leaving the car inside an entrance module.
At peak periods a wait may occur before entering or leaving, because loading passengers and luggage occurs at the entrance and exit rather than at the parking stall. This loading blocks the entrance or exit from being available to others. It is generally not recommended to use automated car parks for high peak hour volume facilities.
Additional factors that need to be taken into consideration are:
- Fear of breakdowns (How does the user get the car back)
- Maintenance contracts needed with suppliers
Other technologies
Modern parking lots utilize a variety of technologies to help motorists find unoccupied parking spaces, car location when returning to the vehicle and improve their experience. This includes adaptive lighting, sensors and parking space LED indicators (red for occupied, green for available and blue is reserved for the disabled; above every parking space), indoor positioning system (IPS), including QR code, and mobile payment options. The Santa Monica Place shopping mall in California has cameras on each stall that can help count the lot occupancy and find lost cars.
Online booking technology service providers have been created to helped drivers find long-term parking in an automated manner, while also providing significant savings for those who book parking spaces ahead of time. They use real-time inventory management checking technology to display parking lots with availability, sorted by price and distance from the airport.
Education & research
In October 2009, the National Building Museum opened an exhibition solely devoted to the study of parking garages (multi-storey car parks) and their impact on the built environment. This exhibition, titled House of Cars: Innovation and the Parking Garage, was on view until 11 July 2010.
See also
- Autostadt
- Auto Stacker
- Automated parking system
- Automatic parking
- Automatic vehicle location
- Car parking system
- Car condo
- Parking guidance and information
- Parking lot
- Trinity Square, Gateshead
References
External links
- "Automatic invisible compact parking. Patent RU 97419".
- Mary Beth Klatt (21 October 2005). "Car culture". Preservation Online. National Trust for Historic Preservation. p. 1. Archived from the original on 11 February 2007. Retrieved 22 February 2007.
- "Robotic Parking Garage: No Tip Necessary "